How to solve the controller errors for beauty machines?
For most chinese supplier , they sell devices and give warranty about 1 year or 2 years mostly. But when the end-user you are meeting with the controller errors, it will be a big headache? How to solve this kind of controller errors for beauty machines? You should find a professional engineer in electronic, then he will be interested in the following analysis:
NO.01-Power supply error!
1.OPT power supply input(220V/110V)wrong;2. The cable is disconnected; 3. The OPT power supply 12V module is abnormal
NO.02-Voltage error!
The control voltage is wrong, usually the control board is damaged by high voltage or electrostatic breakdown。
NO.03-Temperature is too high!
1. The water temperature exceeds the set temperature, the detection temperature is normal, but the set alarm temperature is too low or the set temperature data is abnormal, reset it; 2. Display 00 ° temperature is generally the probe is not connected. 3. If 29° is displayed, some old program control board break will always display 29°.
NO.04-Simmer failure!
1. The OPT gun is broken; reminder: if the wiring is not in conflict, the instrument with two handles can be replaced with another handle to try whether it can work normally, and further locate the fault. 2. The power pre-combustion board is broken. 3. The 2510-8P cable connection from the power board to the pre-combustion board is poor connected.
NO.05-Charge failure !
The capacitor is not fully charged, 1. The power supply is broken; 2. The cable connection is bad; 3. The capacitor is broken. When it is not easy to eliminate the problem, replace the power supply first.
NO.06-Water error!/Or Water flow indicator abnormal
Water flow alarm, 1. The water flow is abnormal, and the pump is broken; 2. The water flow switch is broken; 3. The water flow switch signal line is disconnected. 4. filters are blocked, 5. Controller board signal problem. If the after-sales service is difficult, it is better to turn off the water flow detection function.And work without the water flow also okay.
NO.07-Water level error
Insufficient water flow, the pump is not working, the flow meter is broken (the flow meter can be replaced)
NO.08Foot/switch error
1. The handle button and laser pedal have been kept pressed, or the switch is broken. 2. There is also a phenomenon that the anti-interference diode on the control board is shorted, which can be subtracted with a tool and can be used normally.
NO.09-Handleno detected
The system is equipped with a handle detection function, but no signal can be detected; replace the new handle, or contact an engineer for processing.
NO.10-Replace new handle
To replace with a new handle
NO.11-Maxcounter overflow
The light output count has exceeded the set maximum number of times;
NO.12-Automaticmode timout
Some users add card function to detect timeout
Any more question you may meet welcome to share with Kelly Laser